![Incubatore per micropiastre a 4 posti fino a 80°C - con coperchio Incubatore per micropiastre a 4 posti fino a 80°C - con coperchio](https://www.bioscientifica.it/10139-large_default/incubatore-per-micropiastre-a-4-posti-fino-a-80c-con-coperchio.jpg)
![]() |
||||
You are viewing:
Incubatore per micropiastre a 4 posti fino a 80°C - con coperchio
|
||||
Price
|
Price
€760.00
|
Price
€4,368.00
|
Price
€2,464.00
|
Price
€7,140.00
|
Reference
|
Reference
81 847 0511
|
Reference
BS-010135-AAA
|
Reference
BS-010111-AAA
|
Reference
BS-010425-A01
|
Short description
|
Short description
Incubatore per micropiastre a 4 posti EI-700 - fino a 80°C - con coperchio - Utilizzabile anche con deep-well
|
Short description
Agitatore-incubatore orbitale - Capacità 8 Kg - Temp. fino a 80°CPiattaforme opzionali non incluse
|
Short description
Agitatore-incubatore da banco - Capacità 2,5 Kg - Temp. fino a 42°C - Piattaforme opzionali non incluse
|
Short description
Incubatore CO2 da 46 Lt. Bt Smart Biotherm
|
Manufacturer
|
Manufacturer
Lab Instruments
|
Manufacturer
Biosan
|
Manufacturer
Biosan
|
Manufacturer
Biosan
|
CBT - TYPE
|
CBT - TYPE
incubator
|
CBT - TYPE
incubator
|
CBT - TYPE
incubator
|
CBT - TYPE
incubator CO2
|
CBT - CAPACITY MAX
|
CBT - CAPACITY MAX
4 piastre
|
CBT - CAPACITY MAX
8kg
|
CBT - CAPACITY MAX
1kg
|
|
CBT - VOLUME
|
CBT - VOLUME
nd
|
CBT - VOLUME
ND
|
CBT - VOLUME
46L
|
|
CBT - PLATFORM DIMENSIONS
|
CBT - PLATFORM DIMENSIONS
depending on your choice, approx 35x40cm
|
CBT - PLATFORM DIMENSIONS
selectable choice of, on average, 20x25 cm
|
||
CBT - USEFUL DIMENSIONS INTERNAL
|
CBT - USEFUL DIMENSIONS INTERNAL
460 × 350 × 400 mm
|
CBT - USEFUL DIMENSIONS INTERNAL
305×260×250 mm
|
||
CBT - FLOW
|
CBT - FLOW
8 kg
|
CBT - FLOW
2,5 kg
|
||
CBT - POWER HEATING
|
CBT - POWER HEATING
300W
|
CBT - POWER HEATING
nd
|
||
CBT - TEMPERATURE MAX
|
CBT - TEMPERATURE MAX
80°C
|
CBT - TEMPERATURE MAX
80°C
|
CBT - TEMPERATURE MAX
42°C
|
CBT - TEMPERATURE MAX
60°C
|
CBT - MINIMUM TEMPERATURE
|
CBT - MINIMUM TEMPERATURE
+5°C above ambient
|
CBT - MINIMUM TEMPERATURE
+10°C above ambient
|
CBT - MINIMUM TEMPERATURE
+5°C above ambient
|
|
CBT - MINIMUM TEMPERATURE SETTING
|
CBT - MINIMUM TEMPERATURE SETTING
25°C
|
CBT - MINIMUM TEMPERATURE SETTING
25°C
|
CBT - MINIMUM TEMPERATURE SETTING
25°C
|
|
CBT - RESOLUTION SETTING TEMPERATURE
|
CBT - RESOLUTION SETTING TEMPERATURE
0,1°C
|
CBT - RESOLUTION SETTING TEMPERATURE
0,1°C
|
CBT - RESOLUTION SETTING TEMPERATURE
0.1°C
|
|
CBT - PRECISION
|
CBT - PRECISION
0,5°C
|
CBT - PRECISION
0,5°C
|
CBT - PRECISION
nd
|
|
CBT - UNIFORMITY
|
CBT - UNIFORMITY
0.3°C
|
|||
CBT - COOLING
|
CBT - COOLING
without
|
CBT - COOLING
without
|
CBT - COOLING
without
|
CBT - COOLING
without
|
CBT - AGITATION
|
CBT - AGITATION
with agitation
|
CBT - AGITATION
with agitation
|
CBT - AGITATION
without
|
|
CBT - RANGE RPM
|
CBT - RANGE RPM
50-250
|
CBT - RANGE RPM
from 50 to 250 RPM
|
||
CBT - SPEED MAX
|
CBT - SPEED MAX
max 250 RPM
|
CBT - SPEED MAX
max 250 RPM
|
||
CBT - MOVEMENT
|
CBT - MOVEMENT
orbital
|
CBT - MOVEMENT
orbital
|
||
CBT - ORBIT
|
CBT - ORBIT
20mm
|
CBT - ORBIT
10mm
|
||
CBT - TILT
|
CBT - TILT
-
|
|||
CBT - TECHNOLOGY
|
CBT - TECHNOLOGY
microprocessor
|
CBT - TECHNOLOGY
microprocessor
|
CBT - TECHNOLOGY
microprocessor
|
CBT - TECHNOLOGY
data transfer via Bluetooth
|
CBT - RANGE CO2
|
CBT - RANGE CO2
da 0% a 20%
|
|||
CBT - INCREASES CO2
|
CBT - INCREASES CO2
nd
|
|||
CBT - ACCURACY CO2
|
CBT - ACCURACY CO2
nd
|
|||
CBT - SENSOR
|
CBT - SENSOR
IR
|
|||
CBT - HUMIDITY
|
CBT - HUMIDITY
oltre 90% a 37°C
|
|||
CBT - PRESSURE
|
CBT - PRESSURE
-
|
|||
CBT - INTERFACE
|
CBT - INTERFACE
display
|
CBT - INTERFACE
display
|
CBT - INTERFACE
display
|
CBT - INTERFACE
display
|
CBT - DISPLAY
|
CBT - DISPLAY
LCD
|
CBT - DISPLAY
LCD
|
CBT - DISPLAY
LCD
|
CBT - DISPLAY
digitale
|
CBT - MODE OPERATIONS
|
CBT - MODE OPERATIONS
timed
|
CBT - MODE OPERATIONS
timed / manual
|
CBT - MODE OPERATIONS
timed / manual
|
CBT - MODE OPERATIONS
manual
|
CBT - AUTONOMY
|
CBT - AUTONOMY
nd
|
CBT - AUTONOMY
nd
|
CBT - AUTONOMY
up to 30 days.
|
|
CBT - MEMORY
|
CBT - MEMORY
absent
|
CBT - MEMORY
absent
|
CBT - MEMORY
the black box with the parameters that are logged
|
|
CBT - TIMER
|
CBT - TIMER
1m a 99h
|
CBT - TIMER
1m a 96h / no stop
|
CBT - TIMER
1m a 96h / no stop
|
CBT - TIMER
-
|
CBT - IDEAL IN THE FIELD OF BIOLOGY
|
CBT - IDEAL IN THE FIELD OF BIOLOGY
V
|
|||
CBT - IDEAL FOR INCUBATING CELL CULTURES
|
CBT - IDEAL FOR INCUBATING CELL CULTURES
V
|
|||
CBT - IDEAL FOR INCUBATION
|
CBT - IDEAL FOR INCUBATION
V
|
|||
CBT - IDEAL FOR MIXING AT A CONTROLLED TEMPERATURE
|
CBT - IDEAL FOR MIXING AT A CONTROLLED TEMPERATURE
V
|
|||
CBT - STACKABLE
|
CBT - STACKABLE
no
|
CBT - STACKABLE
no
|
CBT - STACKABLE
using the appropriate accessory
|
|
CBT - PORT EXTERNAL
|
CBT - PORT EXTERNAL
heated
|
|||
CBT - PORT INTERNAL
|
CBT - PORT INTERNAL
glass
|
|||
CBT - INPUTS
|
CBT - INPUTS
no
|
CBT - INPUTS
connection to CO2
|
||
CBT - OUTPUTS
|
CBT - OUTPUTS
no
|
|||
CBT - EXTERIOR MATERIAL
|
CBT - EXTERIOR MATERIAL
construction removable plexiglass
|
|||
CBT - INTERIOR MATERIAL
|
CBT - INTERIOR MATERIAL
stainless steel
|
CBT - INTERIOR MATERIAL
stainless steel
|
||
CBT - DIMENSIONS
|
CBT - DIMENSIONS
340 × 320 × 200 mm
|
CBT - DIMENSIONS
590 × 525 × 510 mm
|
CBT - DIMENSIONS
340x340x435 mm
|
|
CBT - WEIGHT
|
CBT - WEIGHT
4kg
|
CBT - WEIGHT
41.1 kg
|
CBT - WEIGHT
13.2 kg
|
|
CBT - POWER
|
CBT - POWER
220 V 50/60 Hz
|
CBT - POWER
230 V 50/60 Hz
|
CBT - POWER
230 V 50/60 Hz
|
|
CBT - ACCESSORIES INCLUDED
|
CBT - ACCESSORIES INCLUDED
-
|
|||
CBT - OPTIONAL ACCESSORIES
|
CBT - OPTIONAL ACCESSORIES
platforms anti-slip, and with clamps for flasks
|
CBT - OPTIONAL ACCESSORIES
platforms
|
||
CBT - CONFORMITY
|
CBT - CONFORMITY
CE
|
CBT - CONFORMITY
CE
|
CBT - CONFORMITY
CE
|
|
CBT - WARRANTY
|
CBT - WARRANTY
12 months on manufacturing defects
|
CBT - WARRANTY
12 months on manufacturing defects
|
CBT - WARRANTY
12 months on manufacturing defects
|
|
CBT - FEATURES
|
CBT - FEATURES
incubatore specifico per piastre
|
CBT - FEATURES
incubator, shaking, with an optimum energy efficiency for the relatively large
|
CBT - FEATURES
ideal for long operation, for up to 30 days, easy-to-use and dismantled for transport
|